Diversity is only limited by imagination

E-X BOHR RS HT 7,0/6,5xL with washer E19

Stainless self-drilling screws for fixing sandwich panels to wooden substrate

logo2logo1

MATERIALS:
  • Screws are made of stainless steel with drilling point made of surface-hardened carbon steel, zinc plated
  • Washer is made of stainless steel with vulcanized EPDM layer
  • Screw heads and washers may be coated with lacquer coating
INSTALLATION:
  • Maximum drilling capacity in steel up to 2×1,00 mm
  • Anchoring depth in wood min 50 mm
  • For installation, use power screwdriver with a maximum speed of 1500 rpm with regulated torque
  • Screws for corrosivity class C4
  • Screws in class A1 – reaction to fire
TECHNICAL ASSESSMENTS:
  • ETA-13/0181
Product code EAN code D1/DxL hmin hmax Max. drilling capacity Head size Washer diameter Single box Outer cartoon
mm mm mm mm mm mm pcs. pcs.
72081204 0000720812037 7,0/6,5 x 80 10 30 2,00 8 19 250 -
72081404 0000720814031 7,0/6,5 x 100 30 50 2,00 8 19 200 -
72081604 0000720816035 7,0/6,5 x 120 50 70 2,00 8 19 150 -
72081704 0000720817032 7,0/6,5 x 140 70 90 2,00 8 19 150 -
72081804 0000720818039 7,0/6,5 x 160 90 110 2,00 8 19 150 -
72081904 0000720819036 7,0/6,5 x 180 110 130 2,00 8 19 150 -
72082004 0000720820032 7,0/6,5 x 200 130 150 2,00 8 19 150 -
72082104 0000720821039 7,0/6,5 x 220 150 170 2,00 8 19 150 -
72082404 0000720824030 7,0/6,5 x 240 170 190 2,00 8 19 100 -
72082804 0000720828038 7,0/6,5 x 275 205 225 2,00 8 19 100 -
72083004 0000720830031 7,0/6,5 x 300 230 250 2,00 8 19 50 -
MAXIMUM AND MINIMUM THICKNESS OF FIXED ELEMENTS TO WOODEN SUBSTRATE
  • h min - minimum thickness of the fixed elements. Is the sum of: sandwich panel thickness at the fixing point, the insulating tape thickness or saddle washers thickness if any.
  • h max - maximum thickness of the fixed elements. Is the sum of: sandwich panel thickness at the fixing point, the insulating tape thickness or saddle washers thickness if any.
Fastener designation Sandwich panel lining thickness 1), [mm] Characteristic share load, [kN]*
Effective embedment depth in wood hef ≥ 50mm 2)
Sandwich panel thickness
40,00 50,00 60,00 70,00 80,00 100,00 120,00 140,00
E-X BOHR RS HT 6,5xL 0,40 - - - - - - - -
0,50 1,56 1,56 1,56 1,56 1,56 - - -
0,55 1,78 1,78 1,78 1,78 1,78 - - -
0,63 2,13 2,13 2,13 2,13 2,13 - - -
0,75 2,51 2,65 2,65 2,65 2,65 - - -
0,88 2,51 3,14 3,22 3,22 3,22 - - -
1,00 2,51 3,14 3,68 3,74 3,74 - - -


* In order to determine the design resistance characteristic value should be divided by a safety factor of 1.33
1) steel grade S280GD, S320GD, S350GD according to EN 10346
2) construction wood according to EN 14081

Fastener designation Sandwich panel lining thickness 1), [mm] Characteristic tension load, [kN]*
Effective embedment depth in wood hef ≥ 50mm 2)
Sandwich panel thickness
40,00 50,00 60,00 70,00 80,00 100,00 120,00 ≥140,00
E-X BOHR RS HT 6,5xL 0,40 - - - - - - - -
0,50 2,00 2,00 2,00 2,00 2,00 - - -
0,55 2,00 2,00 2,00 2,00 2,00 - - -
0,63 2,00 2,00 2,00 2,00 2,00 - - -
0,75 2,00 2,00 2,00 2,00 2,00 - - -
0,88 2,00 2,00 2,00 2,00 2,00 - - -
1,00 2,00 2,00 2,00 2,00 2,00 - - -


* In order to determine the design resistance characteristic value should be divided by a safety factor of 1.33
1) steel grade S280GD, S320GD, S350GD according to EN 10346
2) construction wood according to EN 14081

EUROPEAN TECHNICAL ASSESSMENT:
DECLARATION OF PERFORMANCE: